The sound started at 2 a.m. in Nelmar Terrace: what each air conditioner noise means, sorted by when you hear it
A house that has been quiet for ten summers makes a new sound in the small hours, and the whole bungalow hears it. The timing of a noise is the best clue to what it is.

Two in the morning, a bungalow, a new sound
The house is a 1920s Craftsman in Nelmar Terrace with the air handler in a hall closet, three feet from the bedroom door. For ten summers it has been a background hum. Tonight, at the start of a cycle, there is a metallic rattle, then a rising screech that settles into a whine, and the homeowner is awake with a flashlight. The question they have is “what is that?” The more useful question is “when does it happen?” A sound at startup, a sound while running, a sound at shutdown and a sound only at night point to different parts.
Noises at startup
A click, then a hum, then nothing from outside. The contactor pulled in but the compressor or fan did not start: a capacitor, most often. Shut it off.
A hard thud or bang from the outdoor unit. The compressor starting against pressure, sometimes a sign of a weak start capacitor, sometimes a compressor with worn internals. Not an emergency once; a pattern worth a visit.
A rattle from the air handler that fades as the blower comes up to speed. A blower wheel loose on its shaft, a panel screw gone, or debris in the wheel. In a closet install it is loud; in an attic you may never hear it.
A buzz at the thermostat or the air handler when the heat is called. A transformer or a relay beginning to fail.
Noises while it runs
A steady screech or whine from the air handler. Blower motor bearings. The motor will fail; the only question is when. In August that is a bad gamble.
A grinding from the outdoor unit. Fan motor bearings, or the fan blade touching the guard after a bump.
A hiss or gurgle near the indoor coil. A refrigerant leak, or in the quieter case, a drain trap bubbling. One is a repair; the other is a vent.
A rattle from the outdoor cabinet. Loose panels, which at Vilano and Crescent Beach usually means corroded screws.
A whistle from registers or the return grille. Airflow restriction: a loaded filter, closed registers, an undersized return in a 1950s Davis Shores closet.

Noises at shutdown and in the quiet after
A thump as the fan stops. Ductwork relaxing. Common in attic installs with long flex runs.
A tick-tick-tick from the outdoor unit after it stops. Metal cooling and contracting. Normal.
A gurgle or drip from the air handler for a minute after. The drain line emptying. Normal, unless it is followed by a puddle.
A click every few seconds from the air handler. A relay chattering on low voltage. Not normal.
Tell us when the sound happens
Noises only at night or only after rain
Night is quieter, so you hear what was always there, but night also brings the heat strips in winter and the longest run cycles in summer, so some noises genuinely are nocturnal. A buzz only on cold mornings is the heat strip sequencer. A squeal only on the longest afternoon runs is a bearing that is heat-sensitive. A rattle only after rain is water in the outdoor fan guard or a float switch cycling the system on and off as a clogged drain fills and empties. Neighbors in the National Register districts, where condensers sit close to bedroom windows, notice a change in the outdoor unit before the owner does; take the comment seriously.
Which of these means call tonight
Humming outside with the fan stopped: shut it off and call. Grinding or screeching from any motor: shut it off and call. Hissing at the coil: call. Burning smell with any noise: shut it off at the breaker and call. Rattles, thumps and ticks: write down when they happen and call in the morning. We answer at 2 a.m. and the price is the same as 2 p.m.; the point of this page is that a noise sorted by timing is a noise we can fix on the first visit.
Noise questions from St. Augustine's quiet streets
There is a loud hum from the outdoor unit but the fan on top isn't moving. Should I shut it off?
Yes, at the thermostat, now. That hum is the compressor trying to run without its fan, usually because the capacitor failed. Left on, it overheats and the repair goes from a small part to a compressor. Then call; the part is on the truck.
Why does the attic unit in our Marsh Creek house thump when it shuts down?
Usually the ductwork relaxing. Flex duct and a plenum that swelled under blower pressure settle when the fan stops, and a loose duct board or a damper blade slaps. Annoying, mostly harmless, and fixable by securing what moves. A thump at startup is a different matter.
The registers whistle since we closed the guest-room vents. Is that harmful?
Open them. The whistle is air forcing through gaps at high pressure, and the pressure is also stressing every duct joint in the attic. Closing registers to move air around a house is how duct leaks start.
Our condenser at Crescent Beach rattles like a tin can. Salt?
Probably. Salt air corrodes the screws and the cabinet panels first, and a panel that has lost two screws drums in the fan’s airflow. We replace hardware with stainless on coastal units and check for the corrosion underneath, which is the real problem.
New noise tonight?
Describe when it happens and we'll tell you whether to shut it off. No after-hours charge.