The FPL bill for the Davis Shores house nobody was in all summer, and what was running while you were gone
A quarter of the people in this city are over 65, and a good many of their houses sit empty from May to October. When the electric bill for an empty house doubles, the air conditioner is the first suspect and not always the guilty one.

The bill arrives in Ohio
The house in Davis Shores was shut in mid-May. Thermostat at 80, shutters closed, water off. The July bill from Florida Power & Light arrives at the owner’s summer address at nearly twice last July’s, and the kilowatt-hour chart on the second page shows the house using more power empty than it did with people in it. Nothing about the owner’s habits changed; they were not there to have habits. Something in the house was running, and running hard.
That bill is one of our most common September calls, and the list of what it might have been is short.
What runs in an empty Florida house
The air conditioner, which should cycle a few times a day to hold 80 and dry the air. The water heater, which should do almost nothing. The refrigerator. A pool pump on a timer. A dehumidifier, if there is one. And whatever was left on by accident. In a house that is working, the air conditioner is most of the bill and the pool pump is most of the rest. In a house with a problem, one of them has gone from a few hours a day to all of them.
The suspects, from biggest draw to smallest
- Electric heat strips running during cooling. A stuck sequencer or relay in the air handler energizes the strips while the compressor runs. The system cools and heats at the same time, around the clock. The biggest single jump we find.
- A compressor on its way out. Worn valves and bearings pull far more current than the nameplate says, for less cooling. Amps tell the story in a minute.
- A refrigerant leak. The system runs continuously trying to reach a setpoint it can hold for only a few minutes at a time. Common on coastal coils in Davis Shores and across the island.
- A dirty or salt-crusted outdoor coil. The unit cannot shed heat, so it runs longer and hotter. Common on any bayfront address that has not had a rinse in a year.
- A pool pump timer stuck on. Not the AC at all, and worth ruling out before any AC part is sold.
- Leaking ductwork. A return pulling 130-degree attic air, or a supply dumping cold air into the attic, forces hours of extra runtime. The 2000s flex duct in World Golf Village and Murabella is reaching the age where this starts.
- A thermostat that lost its program. A power blip resets it to a factory schedule, and 80 becomes 72.

How we find it with a clamp meter and a runtime log
We measure current at the outdoor unit and compare it to the nameplate. We measure at the air handler to see whether the strips are drawing power when they should be dead. We check refrigerant pressures and the coil condition. And we look at runtime: a smart thermostat’s history, or a day of watching the cycles, shows whether the system is running 40 percent of the hours or 95. The combination identifies the cause in one visit, and the price of the fix comes before the fix does.
Before we come: three things to check from your phone
If the house has a connected thermostat, look at its runtime history for the month; a flat line at 100 percent is the answer. Look at the FPL account’s daily usage chart, which shows the day the jump started, often the day a storm rolled through. And ask whoever checks the house to stand at the air handler for a minute while it runs: a warm cabinet during cooling, or hot air from the registers, means the strips are on. Any of those three turns a vague bill complaint into a specific repair, and we can often bring the right part on the first trip.
Bill questions from St. Augustine's part-time residents
The bill doubled and the thermostat was set to 80 all summer. How?
A thermostat setting only controls when the system is asked to run, not how much it draws when it does. A compressor pulling high amps, a coil that cannot shed heat, or strip heat energized by a stuck relay all burn power at 80 as readily as at 74. The setting was fine; something behind it was not.
Could the pool pump at our St. Augustine South house be the jump instead of the AC?
Easily. A single-speed pool pump on a long schedule is one of the largest loads in a Florida house, and a timer that failed to the On position runs it 24 hours a day. We check it, because we would rather tell you to call a pool company than sell you an AC repair you do not need.
Heat strips in July? How would I even know?
You would not, from the thermostat. A stuck sequencer or a miswired thermostat can energize the electric heat strips while the system cools, so the air conditioner fights its own heater. The symptoms are a bill jump and a system that runs constantly. We find it by measuring current at the air handler.
Is a bill jump after we switched to a vacation-rental schedule normal?
Some of it. Guests run the house at 70 with the sliders open. But a rental also hides equipment problems, because nobody who lives there is listening to it. A thermostat with a remote lock and a usage report separates the guest behavior from the equipment trouble.
Bill jumped and nothing changed?
We'll measure what the system actually draws and tell you whether it's the AC at all.